Stellar Apartments, OR

Introduction

Stellar Apartments in Eugene, Oregon was designed with energy efficiency in mind; all of the resident apartment units meet Earth Advantage standards, with one of the 11 residential apartment buildings in the development constructed to be the first multifamily passive building in the country. Monitored utility data is being collected onsite to compare the performance of the passive building with the units built to Earth Advantage standards.

The passive building has a continuous layer of rigid insulation on the exterior sub-sheathing, bulked up R-value batt insulation in the walls, upgraded triple pane windows, and dramatically increased joint sealant, which resulted in an airtightness of 0.4 ACH50.

The 54-unit development consisting of 1, 2 & 3 bedroom apartments was built for the St. Vincent de Paul Society of Lane County, and includes a community building with manager’s unit, bike shelter, playground, and a community garden area.

Project Data
Client/OwnerSt. Vincent de Paul Society of Lane County
LocationEugene, OR
Climate Zone4C
Size (sf)5034
Levels3
Units6
Construction TypeNew Construction
Walls2x6 framing with dense pack fiberglass, plywood sheathing air barrier, and 4" of exterior polyiso (R-47)
Rooftrusses with 29" of loose fill fiberglass (R-89)
Floors12" TJI with dense pack fiberglass (R-51) 
Mechanicals

Heating - zonal electric resistance heaters
Cooling - night flush

Windows

Window Frame - U-0.16 / 0.21: Cascadia 325 series (fiberglass) fixed / casement
Window Glazing - U-0.15 SHGC 0.54: Cardinal 180/180, triple pane, low-e, argon